Iruxol Mono 1.2U/g Ointment Ireland - English - HPRA (Health Products Regulatory Authority)

iruxol mono 1.2u/g ointment

t.j. smith & nephew - clostridiopeptidase a; protease - ointment - 1.2 unit(s)/gram - proteolytic enzymes; collagenase, combinations

Iruxol Mono 1.2U/g Ointment Ireland - English - HPRA (Health Products Regulatory Authority)

iruxol mono 1.2u/g ointment

smith & nephew gmbh - protease; clostridiopeptidase a - ointment - 1.2 unit(s)/gram - proteolytic enzymes; collagenase, combinations

Biosense Webster WEBSTER Duo‐Decapolar Electrophysiology Catheter Singapore - English - HSA (Health Sciences Authority)

biosense webster webster duo‐decapolar electrophysiology catheter

johnson & johnson international (singapore) pte ltd - cardiovascular - the catheter is indicated for electrophysiological mapping of cardiac structures; i.e., stimulation and recording only. in addition, the webster® duo-decapolar catheter is designed to facilitate electrogram mapping in the atrial region of the heart and the coronary sinus.

IntellaTip MiFi Open-Irrigated Ablation Catheter - Catheter, cardiac, ablation Australia - English - Department of Health (Therapeutic Goods Administration)

intellatip mifi open-irrigated ablation catheter - catheter, cardiac, ablation

boston scientific pty ltd - 35855 - catheter, cardiac, ablation - the intellatip mifi open-irrigated ablation catheter is a 7.5f quadrapolar open-irrigated (oi) ablation catheter designed to deliver radiofrequency (rf) energy to the 4.5 mm catheter tip electrode for cardiac ablation. the device includes three diagnostic mini electrodes embedded in the tip electrode that are designed to provide additional high resolution and localized electrogram information. the intellatip mifi oi catheter is indicated for use in patients who require catheterbased cardiac electrophysiological mapping (stimulating and recording) and, when used in conjunction with a rf generator, for cardiac ablation.

LASSO NAV Circular Mapping Catheter - Electrophysiology cardiac catheter, single-use Australia - English - Department of Health (Therapeutic Goods Administration)

lasso nav circular mapping catheter - electrophysiology cardiac catheter, single-use

johnson & johnson medical pty ltd - 46355 - electrophysiology cardiac catheter, single-use - this deflectable catheter consists of a 4.5f circular spine on its distal tip with platinum electrodes that can be used for stimulation and recording. this catheter facilitates electrophysiological mapping of the atria of the heart. it is deployed in the right or left atrium through an 8f guiding sheath. it provides location information when used with compatible carto ep navigation system. the lasso nav (decapolar/twenty electrode) catheter is indicated for multiple electrode electrophysiological mapping of the cardiac structures of the heart, i.e.recording or stimulation only. the catheter is designed to obtain electrograms in the atrial regions of the heart. the lasso nav (decapolar/twenty electrode) catheter provides location information when used with compatible carto ep navigation system.

Activa SC 37603 Muli-program neurostimulator - Brain electrical stimulation system, antitremor Australia - English - Department of Health (Therapeutic Goods Administration)

activa sc 37603 muli-program neurostimulator - brain electrical stimulation system, antitremor

medtronic australasia pty ltd - 37307 - brain electrical stimulation system, antitremor - the neurostimulator is a octapolar, multi-program device that delivers stimulation through one lead. the stimulation settings are stored in programs which are specific combinations of pulse width, rate and amplitude. the device is indicated for stimulation of the ventral intermediate nucleus for patients with disabling essential tremor or parkinsonian tremor, or stimulation of the internal globus pallidus or the subthalamic nucleus for patients with symptoms of parkinson's disease. studies have shown that deep brain stimulation with the medtronic dbs therapy system is effective in controlling essential tremor and symptoms of parkinson's disease that are not adequately controlled with medications. additionally, dbs is effective in controlling dyskinesias and fluctuations associated with medical therapy for parkinson's disease. medtronic dbs therapy for movement disorders is also indicated for stimulation of the internal globus pallidus or the subthalamic nucleus as an aid in the management of chronic, intracta

Blazer Open-Irrigated Ablation Catheter - Catheter, cardiac, ablation Australia - English - Department of Health (Therapeutic Goods Administration)

blazer open-irrigated ablation catheter - catheter, cardiac, ablation

boston scientific pty ltd - 35855 - catheter, cardiac, ablation - the blazer open-irrigated ablation catheter is a 7.5f quadrapolar ablation catheter designed to deliver rf energy to the 4mm tip electrode for cardiac ablation. the catheter incorporates an open-irrigated cooling mechanism through a tip that is partitioned into 2 chambers. the proximal chamber circulates saline within the tip to cool the electrode while the distal chamber allows the fluid to flow through 6 irrigation holes into the patient?s vasculature to cool the tip/tissue interface. the blazer open-irrigated ablation catheter is indicated for use in catheter-based cardiac electrophysiological mapping (stimulating and recording) and, when used in conjunction with a radiofrequency generator, for cardiac ablation.

Activa SC 37603  - Brain electrical stimulation system, antitremor Australia - English - Department of Health (Therapeutic Goods Administration)

activa sc 37603 - brain electrical stimulation system, antitremor

medtronic australasia pty ltd - 37307 - brain electrical stimulation system, antitremor - the neurostimulator is a octapolar, multi-program device that delivers stimulation through one lead. the stimulation settings are stored in programs which are specific combinations of pulse width, rate and amplitude. the device is indicated for stimulation of the ventral intermediate nucleus for patients with disabling essential tremor or parkinsonian tremor, or stimulation of the internal globus pallidus or the subthalamic nucleus for patients with symptoms of parkinson's disease. studies have shown that deep brain stimulation with the medtronic dbs therapy system is effective in controlling essential tremor and symptoms of parkinson's disease that are not adequately controlled with medications. additionally, dbs is effective in controlling dyskinesias and fluctuations associated with medical therapy for parkinson's disease. medtronic dbs therapy for movement disorders is also indicated for stimulation of the internal globus pallidus or the subthalamic nucleus as an aid in the management of chronic, intractable (drug refractory) primary dystonia, including generalised and segmental dystonia, hemidystonia, and cervical dystonia (torticollis) for individuals 7 years of age and older.