Philips 3D Roadmap Singapore - English - HSA (Health Sciences Authority)

philips 3d roadmap

philips electronics singapore pte ltd - cardiovascular - 3d roadmap is a software product (interventional tool) intended to assist the physician during complex interventions by providing live image guidance for navigating endovascular devices through vascular structures anywhere in the body. 3d roadmap is intended to be used in combination with a philips interventional x-ray system. 3d roadmap overlays live 2d fluoroscopic images on a 3d reconstruction of the vessel tree. it can be used during any endovascular intervention and can cover any anatomy, including cerebral, abdominal, and peripheral vasculature. the 3d roadmap is an extension of 3d ra, which provides image guidance by superimposing live fluoroscopic images on a 3d reconstruction of the vessel anatomy to assist in catheter maneuvering. 3d roadmap is suitable for use with the entire human population.

Philips MR-CT Roadmap Singapore - English - HSA (Health Sciences Authority)

philips mr-ct roadmap

philips electronics singapore pte ltd - general hospital - mr-ct roadmap is a software product (interventional tool) intended to provide live 3d image guidance for navigating endovascular devices through vascular structures anywhere in the body, reusing segmented mra or cta data that has been acquired previously. mr-ct roadmap is intended to be used in combination with a philips interventional x-ray system. mr-ct roadmap overlays live 2d fluoroscopic images on a previously acquired mra or cta volume, which is registered with the x-ray system using a rotational scan. it can be used during any endovascular intervention and can cover any anatomy, including for example cerebral, abdominal, and peripheral vasculature. the mr-ct roadmap is an extension of 3d ra, which provides image guidance by superimposing live fluoroscopic images on a 3d reconstruction of the vessel anatomy to assist in catheter maneuvering. mr-ct roadmap is suitable for use with the entire human population.

Philips Dynamic Coronary Roadmap Singapore - English - HSA (Health Sciences Authority)

philips dynamic coronary roadmap

philips electronics singapore pte ltd - cardiovascular - dynamic coronary roadmap is intended to assist the physician during percutaneous coronary interventions in correlating the device position to the coronary vasculature, by providing a motion compensated overlay of this coronary vasculature. the ffr/ifr roadmap feature is intended to assist the physician during percutaneous coronary interventions in relating the intravascular blood pressure measurement to its anatomical location. ffr/ifr roadmap visualizes the position of the pressure wire and the coronary artery on an x-ray image at the moment that an intravascular blood pressure measurement was performed as well as the intravascular blood pressure measurement values themselves. dynamic coronary roadmap is suitable for use with the entire adult human population.

SYNFLORIX SUSPENSION Canada - English - Health Canada

synflorix suspension

glaxosmithkline inc - pneumococcal polysaccharide serotype 1 conjugated to protein d carrier protein; pneumococcal polysaccharide serotype 4 conjugated to protein d carrier protein; pneumococcal polysaccharide serotype 5 conjugated to protein d carrier protein; pneumococcal polysaccharide serotype 6b conjugated to protein d carrier protein; pneumococcal polysaccharide serotype 7f conjugated to protein d carrier protein; pneumococcal polysaccharide serotype 9v conjugated to protein d carrier protein; pneumococcal polysaccharide serotype 14 conjugated to protein d carrier protein; pneumococcal polysacc. serot. 18c conjug. to tetanus toxoid carrier prot.; pneumococcal polysaccharid serot. 19f conjug. to diphtheria toxoid carrier prot.; pneumococcal polysaccharide serotype 23f conjugated to protein d carrier protein - suspension - 1mcg; 3mcg; 1mcg; 1mcg; 1mcg; 1mcg; 1mcg; 3mcg; 3mcg; 1mcg - pneumococcal polysaccharide serotype 1 conjugated to protein d carrier protein 1mcg; pneumococcal polysaccharide serotype 4 conjugated to protein d carrier protein 3mcg; pneumococcal polysaccharide serotype 5 conjugated to protein d carrier protein 1mcg; pneumococcal polysaccharide serotype 6b conjugated to protein d carrier protein 1mcg; pneumococcal polysaccharide serotype 7f conjugated to protein d carrier protein 1mcg; pneumococcal polysaccharide serotype 9v conjugated to protein d carrier protein 1mcg; pneumococcal polysaccharide serotype 14 conjugated to protein d carrier protein 1mcg; pneumococcal polysacc. serot. 18c conjug. to tetanus toxoid carrier prot. 3mcg; pneumococcal polysaccharid serot. 19f conjug. to diphtheria toxoid carrier prot. 3mcg; pneumococcal polysaccharide serotype 23f conjugated to protein d carrier protein 1mcg - vaccines

Canon Infinix-i INFX-8000C CC-i interventional angiography system Singapore - English - HSA (Health Sciences Authority)

canon infinix-i infx-8000c cc-i interventional angiography system

canon medical systems asia pte., ltd. - radiology / imaging - intended for multidirectional observation of the flow of contrast medium injected into the blood vessels of a patient. designed for selective cardiac angiography (with catheterization). this system is intended for use in interventional procedures for cardiac vessels, such as pci, and also for use in ep (electrophysiological) studies.

Canon Infinix-i INFX-8000C VC-i interventional angiography system Singapore - English - HSA (Health Sciences Authority)

canon infinix-i infx-8000c vc-i interventional angiography system

canon medical systems asia pte., ltd. - radiology / imaging - intended for multidirectional observation of the flow of contrast medium injected into the blood vessels of a patient. designed for selective angiography (with catheterization) of the head, abdomen, and lower extremities. this system is intended for use in interventional procedures, such as embolization, for blood vessels in the head, abdomen, and lower extremities.

Canon Infinix-i INFX-8000V CF-i interventional angiography system Singapore - English - HSA (Health Sciences Authority)

canon infinix-i infx-8000v cf-i interventional angiography system

canon medical systems asia pte., ltd. - radiology / imaging - intended for multidirectional observation of the flow of contrast medium injected into the blood vessels of a patient. designed for selective cardiac angiography (with catheterization). this system is intended for use in interventional procedures for cardiac vessels, such as pci, and also for use in ep (electrophysiological) studies.

Canon Infinix-i INFX-8000V VF-i interventional angiography system Singapore - English - HSA (Health Sciences Authority)

canon infinix-i infx-8000v vf-i interventional angiography system

canon medical systems asia pte., ltd. - radiology / imaging - intended for multidirectional observation of the flow of contrast medium injected into the blood vessels of a patient. designed for selective angiography (with catheterization) of the head, abdomen, and lower extremities. this system is intended for use in interventional procedures, such as embolization, for blood vessels in the head, abdomen, and lower extremities.

X-ray system, diagnostic, fluoroscopic, angiographic, application program software Australia - English - Department of Health (Therapeutic Goods Administration)

x-ray system, diagnostic, fluoroscopic, angiographic, application program software

philips electronics australia ltd - 40868 - x-ray system, diagnostic, fluoroscopic, angiographic, application program software - intended to assist the physician during percutaneous coronary interventions in correlating the device position to the coronary vasculature, by providing a motion compensated overlay of this coronary vasculature. the ffr/ifr roadmap feature is intended to assist the physician during percutaneous coronary interventions in relating the intravascular blood pressure measurement to its anatomical location. ffr/ifr roadmap visualizes the position of the pressure wire and the coronary artery on an x-ray image at the moment that an intravascular blood pressure measurement was performed as well as the intravascular blood pressure measurement values themselves.

X-ray system, diagnostic, fluoroscopic, angiographic, application program software Australia - English - Department of Health (Therapeutic Goods Administration)

x-ray system, diagnostic, fluoroscopic, angiographic, application program software

philips electronics australia ltd - 40868 - x-ray system, diagnostic, fluoroscopic, angiographic, application program software - intended to assist the physician during percutaneous coronary interventions in correlating the device position to the coronary vasculature, by providing a motion compensated overlay of this coronary vasculature. the ffr/ifr roadmap feature is intended to assist the physician during percutaneous coronary interventions in relating the intravascular blood pressure measurement to its anatomical location. ffr/ifr roadmap visualizes the position of the pressure wire and the coronary artery on an x-ray image at the moment that an intravascular blood pressure measurement was performed as well as the intravascular blood pressure measurement values themselves. suitable for use with the entire adult human population.