aideel sacha inchi oil plus softgel
aifa health sdn.bhd. - dl alpha tocopheryl acetate; plukenetia volubilis (sacha inchi) seed oil -
laider bone cement instrument set
land mover medical pte ltd - general hospital - the bone cement instrument set is applicable for bone cement mixing and injecting into vertebral body.
raider guidewire - catheter guide wire
teleflex medical australia pty ltd - 35094 - catheter guide wire - the raider guidewire is a 0.014" diameter stainless steel core guidewire with a non-tapered distal tip. it is available in 200cm and 300cm lengths. the distal 25cm of the guidewire has a spring coil, of which the distal 10cm is platinum and visible under fluoroscopic methods. the guidewire has a straight shapeable tip with a tip load of 4 grams. the distal 30cm of the guidewire is polymer jacketed with a hydrophilic coating, and the proximal portion has a ptfe coating. the raider guidewire is intended for use in percutaneous procedures to introduce and position catheters and other interventional devices within the coronary and peripheral vasculature.
braided polyester non absorbable suture - suture, polyester
boston scientific pty ltd - 13906 - suture, polyester - the braided polyester non absorbable suture is placed using a needle holder. the needle end of the suture is grasped using a needle holder and then driven through the tissue. the needle point is then removed and the suture tied using standard surgical procedure. these sutures are gradually encapsulated by fibrous connective tissue but are not absorbed into the body indicated for use in general soft tissue approximation and/or ligation, including use in cardiovascular, opthalmic, orthopaedic and neurological procedures
braided tape - prosthesis, internal, intracardiac, patch
bard australia pty ltd - 31744 - cardiovascular patch, synthetic - bard surgical tapes are made of ptfe or polyester yarns and are tightly braided in construction. intended for purposes of tissue approximation, retraction, and as a temporary or permanent ligature.
hearing aid wireless-fitting computer-aided set
starkey laboratories australia pty ltd - 57884 - hearing aid wireless-fitting computer-aided set - a collection of devices designed to work in conjunction with a computer to transmit wireless data to a hearing aid for computer-aided adjustment of the hearing aid while it is being fitted to a patient by healthcare personnel. it primarily consists of computer application software and a neck loop to establish the wireless link (the radio link protocol) with the hearing aid. the hearing aid must be compatible for wireless data reception and may be behind-the-ear (bte), in-the-ear (ite) and completely-in-the-canal (cic) types.
hearing aid wireless-fitting computer-aided set
sonova australia pty ltd - 57884 - hearing aid wireless-fitting computer-aided set - a collection of devices designed to work in conjunction with a a computer to transmit wireless data to a hearing aid for computer-aided adjustment of the hearing aid while it is being fitted. the hearing aid must be compatible for wireless data reception and may be behind-the-ear (bte), in-the-ear (ite) and completely-in-the-canal (cic) types
hearing aid wireless-fitting computer-aided set
ws audiology anz pty ltd - 57884 - hearing aid wireless-fitting computer-aided set - a device designed to work in conjunction with a computer to transmit wireless data to a hearing aid for computer-aided adjustment of the hearing aid while it is being fitted to a patient by healthcare personnel.
?ftlc braided angiography catheters - catheter, angiography
getz healthcare pty ltd - 10688 - catheter, angiography - braided angiography catheters use the reference ?ftlc. this corresponds to : ? (diameter in french unit) + t + l (length in cm) + c (the name of the curve). braided catheters have stainless steel mesh reinforcement in the plastic matrix and a supple distal tip. angiographic catheters are designed for selective catheterisation of concerned vessels. the different lengths and sizes allow adaptability to each situation. angiographic catheters are radio-opaque. angiographic catheters are designed for selective or global angiographic examinations and therapeutic embolisations.
omnia silk braided-wax treated non-absorbable sterile surgical suture
cantel medical asia/pacific pte. ltd. - general & plastic surgery - braided non absorbable silk suture is indicated for use in all types of soft tissue approximation and/or ligation, including dental and general surgeries. the device is not indicated for use in cardiovascular surgery, ophthalmic surgery, microsurgery and for the application in neural tissues.